KD5500

KD5500

Model Unit KD5500
GENERATOR
Design — Bi-Gen RF2 – 7.5 Permanent Magnet (PM)
Brushless type, 2 pole
Frequency Hz 50
Rated Output (COP)
kVA 5.5
kW 5.5
Rated Voltage V 240
Rated Amperagey A 22.9
Phase & Wire ø-W 1-2
Rated Power Factor – 1.0
Total Harmonic Distortion % < 6 (full load)
Type of Coupling — Direct coupled
DIESEL ENGINE
Model — OC95
Design — Vertical, TVCS, 3 vortex combustion
No. of cylinders — 1
Bore x stroke mm (in.) ø 83 x 77 (3.27 x 3.03)
Displacement L (cu. in.) 0.416 (25.42)
Engine speed rpm 3000
Lubricating Oil — API service class CF or higher
Oil capacity L 1.7
Coolant system — Oil cooling + Air cooling
SET
Fuel — Diesel fuel No. 2 (ASTM D975)
Fuel consumption (at full load) L /h 1.93
Fuel tank capacity L 5.5
Continuous Operating Hours (at full load) hrs 2.85
Battery — 12V 36-48Ah
Starting System — Electric
L x W x H mm 566 x 664 x 718
Approx Net Wt. kg 132
Receptacles — 2 x 15A Single phase sockets, IP66 rated
Electrical Protection — 16A RCBO 30mA (2Pole) x 2, Earth-Neutral Link

This product is not available for purchasing online. Please make an enquiry for purchasing information.